High-Performance Electrofusion Fittings for Industrial & Municipal Piping Systems

Primary Function:

Permanent, leak-free jointing for high-density polyethylene (HDPE) pressure piping networks through electrical resistance heating.

 

Applicable Piping Systems:

PE80 and PE100 HDPE pressure pipes for potable water, natural gas distribution, wastewater, and industrial process fluids.

 

Target Purchasers:

Municipal utility contractors, gas network operators, wholesale piping distributors, and EPC project managers.

 
 
  • HDPE Electrofusion Fittings
    Each electrofusion fitting is embedded with resistance wires evenly distributed within its wall. When energized, these wires generate gradual heat, melting the thin contact interface between the
  • Electro Fusion Fittings
    Every electrofusion fitting comes with resistance wires fitted evenly inside the fitting wall. When connected to a power source, the wires heat up gradually, reaching a temperature that melts the
  • Electro Fusion Joint HDPE
    Embedded evenly within the wall of every electrofusion fitting, resistance wires activate and produce gentle heat once power is supplied. This heat melts the mating area between the fitting and pipe.
  • Poly Electrofusion Fittings
    This electrofusion coupler features stable chemical resistance, excellent anti-corrosion performance and high impact strength. It is easy to install, suitable for gas supply, water supply and mining
  • HDPE Electrofusion Equal Tee Fittings
    These fittings are built with a solid main body and integrated resistance ring, made with standard, durable components. For easier on-site use, select models include barcodes that lock in automatic
  • Electrofusion Reducing Tee Fittings
    The process is straightforward, really. Energize the fitting, let the wires heat up, wait for the surfaces to melt, then allow it to cool. leak-proof seal—simple, effective, and no extra steps.
  • Electrofusion Coupler
    Every electrofusion fitting comes with resistance wires fitted evenly inside the fitting wall. When connected to a power source, the wires heat up gradually, reaching a temperature that melts the
 
Product Types & Specifications

 

Product Type

Size Range (mm)

Material Grade

Connection Type

Applicable Standards

Electrofusion Coupler

20 - 1200

PE100 / PE100-RC

Socket Fusion

ISO 4427-3, EN 1555-3, ISO 8085

Electrofusion Elbow (90° / 45°)

20 - 315

PE100 / PE100-RC

Socket Fusion

ISO 4427-3, EN 1555-3

Electrofusion Equal / Reducing Tee

25 - 315

PE100 / PE100-RC

Socket Fusion

ISO 4427-3, EN 1555-3

Electrofusion Reducer

32 × 25 - 400 × 315

PE100 / PE100-RC

Socket Fusion

ISO 4427-3, EN 1555-3

Electrofusion Tapping Saddle

63 × 20 - 315 × 63

PE100 / PE100-RC

Integrated Cutter / Saddle

ISO 8085, EN 1555-3

 

Applications
 
 
 

Municipal Water Networks:

Potable water transmission mains, distribution branches, and municipal service connections.

 
 

Gas Distribution:

Underground natural gas and biogases distribution networks operating under stringent safety codes.

 
 

Industrial Fluid Transport:

Chemical effluent lines, slurry transport, and cooling water loops in industrial plants.

 
 

Operating Conditions:

Rated for water up to PN16 / SDR11 (1.6 MPa) and gas up to PN10 (1.0 MPa) at 20°C. Operating temperature range: -20°C to +40°C.

 

 

Compatibility & Selection Guide

Pipe Material Matching:

Compatible with PE80, PE100, and PE100-RC pipes conforming to ISO 4427 and EN 12201. Fusion parameters are validated for virgin black or blue-striped PE resins.

SDR & Wall Thickness Alignment:

Ensure fitting SDR matches pipe SDR (e.g., SDR11 fitting for SDR11 pipe) to maintain uniform internal pressure ratings and avoid misalignment during fusion.

Welding Equipment Requirements:

Standard 40V output electrofusion control boxes with automatic barcode scanning or manual voltage input.

Selection Parameters:

Verify pipe outer diameter, operating pressure, fluid type, and ambient installation temperature prior to ordering.

 

Quality Control & Compliance
 

Resin Verification: Incoming virgin PE100/PE100-RC raw materials (Borouge, Borealis, or equivalent) undergo melt mass-flow rate (MFR) and density testing per ISO 1133 and ISO 1183.


Dimensional Inspection: Automated laser gauges monitor socket inner diameter, wall thickness, and ovality across every production batch.


Destructive & NDT Testing: Routine peel tests (ISO 13953) and tensile shear impact tests (ISO 13950) conducted on welded samples every 4 hours to verify fusion integrity.


Traceability: Each fitting is laser-marked with a unique 24-digit barcode containing raw material lot, molding date, and fusion parameters.

HDPE Electrofusion Fittings

 

Electrofusion HDPE Pipe Fittings

Compliance Standards & Certifications:
Standards: ISO 4427-3, EN 1555-3, ISO 8085.


Certifications: ISO 9001:2015 Quality Management System, WRAS (Water Regulations Advisory Scheme) for potable water contact, and CE Certification.


Manufacturing Context: Produced via precision CNC injection molding utilizing multi-cavity European mold tooling, backed by automated cooling control systems to eliminate internal residual stresses.

 

OEM/ODM & Customization
Dimensional Adjustments:
Custom spigot lengths and specialized transition fittings for non-standard trench layouts.
Marking & Packaging:
Customized laser etching of client logos, part numbers, and project-specific barcodes. Polybag and reinforced carton packaging designed for container export.
Color Coding:
Standard black (gas/water), blue stripe (water), or yellow stripe (gas) configurations available upon request.

 

 

Ordering Information

Specification Confirmation: Provide exact outer diameter, SDR rating, gas/water designation, and required quantity.


Technical Documentation: Dimensional CAD drawings and raw material test certificates (3.1 Test Certificate per EN 10204) supplied upon PO confirmation.


Minimum Order Quantity (MOQ): Varies by fitting size (e.g., 500 pcs for small diameters 20–63 mm; 20 pcs for large diameters >315 mm).


Lead Time: 20 to 30 days for standard container loads.


Samples: Free samples available for laboratory testing; freight charges apply.

HDPE Electrofusion Equal Tee Fittings

 

 

FAQ

 

 

Q: Are these fittings compatible with both PE80 and PE100 pipes?

A: Yes. PE100 electrofusion fittings are fully compatible with PE80 and PE100 pipes of the same outer diameter and correct wall thickness ratio.

Q: What is the standard welding voltage for these fittings?

A: Standard operating voltage is 40V. Each fitting features a barcode containing energy input data readable by standard electrofusion control boxes.

Q: What raw material grades are used in production?

A: Production utilizes virgin PE100 and PE100-RC (resistant to crack) base resins with certified MRS ≥ 10 MPa.

Q: How is traceability managed for job-site quality audits?

A: Every fitting displays a permanent, machine-readable barcode detailing the resin batch, production shift, and precise fusion welding parameters.

Q: What independent quality certifications do you hold?

A: Products comply with ISO 4427-3, EN 1555-3, and hold WRAS, CE, and ISO 9001 certifications.

Q: Can these fittings be installed in cold weather environments?

A: Yes, provided installation follows standard procedures. Ambient temperatures below -5°C require tenting or pre-heating protocols as outlined in ISO 13955.

 

modular-1
Request a Quote

Submit your specification requirements—including pipe diameter, SDR rating, quantity, and destination port—to receive a commercial quotation and technical datasheet within 24 hours.

As one of the most professional electrofusion fittings manufacturers and suppliers in China, we have world-leading production equipment and strong manufacturing capabilities. Please feel free to buy bulk high quality electrofusion fittings from our factory.

Electro Fusion Fittings, Electrofusion Coupler, electrofusion fittings
Send Inquiry